2.8.2.5. Block 11 — OPCIN — Channel-Independent Floating-Point Input¶
EPSTEM
1
K
Steady-state temperature convergence delta. The steady-state temperatures in the fuel-pin must converge such that |T’ - T| <= EPSTEM
, where T’ is the temperature on the last iteration and T is the temperature on the previous iteration.
Suggested value: 0.1.
EPSREA
2
Not currently used.
EPSPOW
3
Neutron flux amplitude convergence criterion.
EPSGAM
4
Not currently used.
DT0
5
s
Initial and maximum main time step length.
DTMXB
6
s
Maximum heat-transfer time step length after coolant boiling inception.
Suggested value: 0.01 s.
Maximum value: 0.02 s.
REAITR
8
Not currently used.
DTFUEL
10
K
DTCLAD
11
K
Maximum cladding temperature change per heat-transfer time step.
Suggested value: 30.0.
TCLMAX
12
Not currently used.
DTP0
13
s
Initial PRIMAR time step size.
DTPMAX
14
s
Maximum PRIMAR time step size before boiling starts.
DTPBOI
15
s
Maximum PRIMAR step size after start of boiling.
DTPLEV
16
s
Maximum PRIMAR step size after LEVITATE starts.
DTPFCI
17
s
Maximum PRIMAR step size after PLUTO-2 starts.
DPINMX
19
Pa
Maximum change in inlet pressure per PRIMAR step.
DTINMX
20
K
Maximum change in inlet temperature per PRIMAR step.
DTMMXB
21
s
Maximum main time step after the onset of boiling.
ASCRAM
23
Not currently used.
GSCRAM
25
Not currently used.
DTSSCP
26
s
Time step size for the null transient to initialize component-component heat transfer in PRIMAR-4.
EPSSCP
27
Component-component heat transfer convergence criterion for the null transient.
DXMAPR
28-87
Not currently used.
DTNULL
88
s
Time step size for the null transient for steady-state core channel thermal hydraulics.
Not used if ISSNUL
=0.
TPCOST
89
s
Time to start writing PINACLE data for core image (PNPICO subroutine).
TPCOLE
90
s
Time to start writing LEVITATE data for core image (LEPICO subroutine).
TPCOEN
91
s
Time to stop writing data for core images.
DTPICP
92
s
Time interval for writing data for core images while PINACLE is active.
DTPICL
93
s
Time interval for writing data for core images while LEVITATE is active.
DTMIN (I)
95-104
s
Main time step table. DTMIN
(I) is the length of the main time step to be used in the problem time interval from TDTMIN
(I) to TDTMIN
(I+1). For times before TDTMIN
(1), DT0
is used as the main time step. If J is the index of the last entry in the DTMIN
table, then the main time step for times after TDTMIN
(J) is DTMIN
(J). If there are no entries in the DTMIN
table, the automatic main time step selection algorithm will be used.
TMAINS
115-149
s
Problem times for forced main time step termination.
DELSCR
150
s
DELPUM
151
s
PUHALF
152
s
OPCDUM
153-250
Not currently used.
DEFAULT VALUES
1.0 |
|
0.01 |
|
0.004 |
|
0.001 |
|
0.05 |
|
25000.0 |
|
5.0 |
|
1.0 |
|
0.02 |