2.8.2.12. Block 61 — GEOMIN — Channel-Dependent Geometry Data
1-7
ACCZ (KZ)
m^2
Coolant flow area per fuel-pin in zone KZ. For example, core plus axial blankets plus fission-gas plenum, i.e., the whole fuel-pin length, is one zone. Each axial reflector is a separate zone.
8-31
AXHI (J)
m
Length of axial segment J, 1 ≤ J ≤ MZ. MZ is the number of axial segments in core plus blankets.
Note: All should be as equal in size as possible. MFUEL (IFUELO
= 2) requires this dimension to be defined based on as-fabricated dimensions.
32-38
DHZ (KZ)
m
Hydraulic diameter in zone KZ.
39-45
DSTIZ (KZ)
m
DSTI (thickness of inner structure node) in zone KZ. (See FNSROS
for consistent input).
46-52
DSTOZ (KZ)
m
DSTO (thickness of outer structure node) in zone KZ. (See FNSROS
for consistent input)
53
PLENL
m
Length of fission-gas plenum. Note: MFUEL (IFUELO
= 2) requires this dimension to be defined based on as-fabricated dimensions.
54-77
RBR (J)
m
Cladding inner radius for axial segment J, 1 ≤ J ≤ MZ.
Note: If all values are the same, only the first must be input. MFUEL (IFUELO
= 2) requires this dimension to be defined based on as-fabricated dimensions.
78-101
RER (J)
m
Cladding outer radius for axial segment J, 1 ≤ J ≤ MZ.
Note: If all values are the same, only the first must be input. MFUEL (IFUELO
= 2) requires this dimension to be defined based on as-fabricated dimensions.
102
RBRPL
m
Cladding inner radius in gas plenum. Note: MFUEL (IFUELO
= 2) requires this dimension to be defined based on as-fabricated dimensions.
103
RERPL
m
Cladding outer radius in gas plenum. Note: MFUEL (IFUELO
= 2) requires this dimension to be defined based on as-fabricated dimensions.
104-127
RINFP (J)
m
128-151
ROUTFP (J)
m
Fuel outer radius for axial segment J, 1 ≤ J ≤ MZ.
Note: If all values are the same, only the first must be input. MFUEL (IFUELO
= 2) requires this dimension to be defined based on as-fabricated dimensions.
152-158
ZONEL (KZ)
m
Length of zone KZ.
159-165
SRFSTZ (KZ)
m
SFR, structure perimeter in zone KZ per pin.
166
AREAPC
m^2
APC, coolant plus pin area per pin, in the pin section.
169-175
DRFO (KZ)
m
KZ = 1, NZONE. For KZ not equal to KZPIN , DRFO
is the thickness of the outer reflector node in zone KZ. Note that a two-node, slab-geometry treatment is used for heat transfer to the reflector. (See DRFI
for the inner node thickness).
For KZ = KZPIN, DRFO
= cladding thickness in the plenum region (RERPL
- RBRPL
).
176
STCOR
Not currently used.
177
VFPLNT
Not currently used.
178
VFLREF
Not currently used.
179
VFUREF
Not currently used.
180
RBR0
m
Nominal cladding inner radius.
181
RER0
m
Nominal cladding outer radius.
182-188
SER (KZ)
m
196
VFC
Not currently used.
197-220
RAFUZ
Not currently used.
221
ZCHOBT
Axial coordinates lower end of the hodoscope field of view referenced to the fuel pin bottom. Used only for TREAT experiment analysis.
222
ZCHOTP
Axial coordinates upper end of the hodoscope field of view referenced to the fuel pin bottom. Used only for TREAT experiment analysis.
223
ZOFFST
m
Axial (Z) offset, elevation of the bottom of the lower blanket. Default = 0.
224-247
RIZNC (J)
m
248-271
RIZNM (J)
m
272
TWASTI
m
Initial wastage thickness on the cladding inner surface. Used in DEFORM-5 and FPIN2.
273
TWASTO
m
Initial wastage thickness on the cladding outer surface. Used in DEFORM-5 and FPIN2.
274
XXNPIN
275-284
DZEMFM
See FED.
285-350
DUMGEO
Not currently used.