2.8.2.5. Block 11 — OPCIN — Channel-Independent Floating-Point Input
1
EPSTEM
K
Steady-state temperature convergence delta. The steady-state temperatures in the fuel-pin must converge such that |T’ - T| <= EPSTEM
, where T’ is the temperature on the last iteration and T is the temperature on the previous iteration.
Suggested value: 0.1.
2
EPSREA
Not currently used.
3
EPSPOW
Neutron flux amplitude convergence criterion.
4
EPSGAM
Not currently used.
5
DT0
s
Initial and maximum main time step length.
6
DTMXB
s
Maximum heat-transfer time step length after coolant boiling inception.
Suggested value: 0.01 s.
Maximum value: 0.02 s.
8
REAITR
Not currently used.
10
DTFUEL
K
11
DTCLAD
K
Maximum cladding temperature change per heat-transfer time step.
Suggested value: 30.0.
12
TCLMAX
Not currently used.
13
DTP0
s
Initial PRIMAR time step size.
14
DTPMAX
s
Maximum PRIMAR time step size before boiling starts.
15
DTPBOI
s
Maximum PRIMAR step size after start of boiling.
16
DTPLEV
s
Maximum PRIMAR step size after LEVITATE starts.
17
DTPFCI
s
Maximum PRIMAR step size after PLUTO-2 starts.
19
DPINMX
Pa
Maximum change in inlet pressure per PRIMAR step.
20
DTINMX
K
Maximum change in inlet temperature per PRIMAR step.
21
DTMMXB
s
Maximum main time step after the onset of boiling.
23
ASCRAM
Not currently used.
25
GSCRAM
Not currently used.
26
DTSSCP
s
Time step size for the null transient to initialize component-component heat transfer in PRIMAR-4.
27
EPSSCP
Component-component heat transfer convergence criterion for the null transient.
28-87
DXMAPR
Not currently used.
88
DTNULL
s
Time step size for the null transient for steady-state core channel thermal hydraulics.
Not used if ISSNUL
=0.
89
TPCOST
s
Time to start writing PINACLE data for core image (PNPICO subroutine).
90
TPCOLE
s
Time to start writing LEVITATE data for core image (LEPICO subroutine).
91
TPCOEN
s
Time to stop writing data for core images.
92
DTPICP
s
Time interval for writing data for core images while PINACLE is active.
93
DTPICL
s
Time interval for writing data for core images while LEVITATE is active.
95-104
DTMIN (I)
s
Main time step table. DTMIN
(I) is the length of the main time step to be used in the problem time interval from TDTMIN
(I) to TDTMIN
(I+1). For times before TDTMIN
(1), DT0
is used as the main time step. If J is the index of the last entry in the DTMIN
table, then the main time step for times after TDTMIN
(J) is DTMIN
(J). If there are no entries in the DTMIN
table, the automatic main time step selection algorithm will be used.
115-149
TMAINS
s
Problem times for forced main time step termination.
150
DELSCR
s
151
DELPUM
s
152
PUHALF
s
153
OPCDUM
Not currently used.
154
GRAVITY
m/s^2
Acceleration of gravity. Default: 9.81 m/s^2
155
ADJKTOL
156-250
OPCDUM
Not currently used.
DEFAULT VALUES
1.0 |
|
0.01 |
|
0.004 |
|
0.001 |
|
0.05 |
|
25000.0 |
|
5.0 |
|
1.0 |
|
0.02 |